Users requesting GVI data from SSB should make every effort to supply as much information as possible concerning their needs. If possible, requestors should specify the SSB tape numbers of the tapes to be copied.
Frequently, orders contain incomplete or ambiguous information, which results in delays or improper filling of orders. Proper identification of desired data on magnetic tapes is important because of the high data densities frequently encountered and large volumes of tapes. The following information should be furnished in preparing orders for data to ensure timely and correct completion:
1. Time period of interest. The earliest GVI products were produced for the week of May 10, 1982. Appendices C and D list the time periods for which the First Generation and Second Generation GVI products, respectively, were computed and notes days for which data are not available. Appendix D will be updated periodically; the user may contact SSB for more current information if desired.
2. Which products are desired (see Table 6.0-1):
Table 6.0-1. List of available GVI products. |
|||
Generation/ type | Frequency (type) | Projection | Variables reported |
Third/digital (See Section 5) |
Weekly (B-level) | Plate Carrée | Ch1 reflectances Ch2 reflectances Ch4 brightness temperatures Ch5 brightness temperatures Quality/Cloud SCA SZA PWI NDVI |
Monthly (C-level) | Plate Carrée | Ch1 reflectances Ch2 reflectances Ch4 brightness temperatures Ch5 brightness temperatures NOBS SCA SZA PWI NDVI |
|
Climatology (D-level) | Plate Carrée | Means and standard deviations for: Ch1 reflectances Ch2 reflectances Ch4 brightness temperatures Ch5 brightness temperatures SCA SZA PWI NDVI |
|
Second/ digital (See Section 4.4) | Daily | Plate Carrée | Ch1 Ch2 Ch4 Ch5 SCA SZA |
Weekly | Polar Stereo and Mercator | NDVI Ch1 Ch2 Ch4 Ch5 SCA SZA |
|
Weekly | Plate Carrée | NDVI CVI Ch1 Ch2 Ch4 Ch5 SCA SZA Stacked NDVI Continental Weekly Composite |
|
First/ Imagery (See Section 3.2) | Daily | Polar Stereo | Ch2 Ch2-Ch1 |
Weekly | Polar Stereo | NDVI Ch1 Ch2 Stacked NDVI |
|
First GVI/ digital (See Section 3.1) | Daily | Polar Stereo | Ch2 Ch2-Ch1 |
Weekly | Polar Stereo | NDVI Ch1 Ch2 Stacked NDVI |
3. In what form the products are desired: digital on either IBM 3480 cartridge; 4mm DAT; 8mm Exabyte tape; or CD-ROM; hardcopy (if available), or both.
NCDC representatives will take telephone orders and inquiries from approximately 0730 to 1630 Eastern Time, Monday through Friday (except U.S. holidays) at (828) 271-4800. The fax number is (828) 271-4876. Also, Internet can be used to send an electronic message using the following address: satorder@ncdc.noaa.gov.
Payment is to be made in U.S. funds only, in the form of a check or money order made out to "Commerce/NOAA/NCDC", or VISA or MASTERCARD. Repeat users are urged to set up an account with NCDC (minimum deposit of $1000) to draw upon.
Orders not accompanied by pre-payment will not be processed until full payment is received. U.S. Federal Government Agencies must supply a Purchase Order or MIPR (USA Dept. of Defense contract) with each request.
NOAA organizations must furnish a valid organization code and task number to be billed.
Completed orders are sent via regular mail to domestic customers and via Air Mail to overseas customers; orders valued at more than $250 (U.S.) are sent Registered or Certified Mail. NCDC also has the capability to deliver orders to most areas of the United States, some Canadian locations, and major cities in most Foreign countries, by several different express delivery companies (overnight or two to three days). If any of these express delivery services are requested by the data user, the customer will assume all delivery charges. Delivery to foreign nations can also be made through each nation's Scientific Attaché located at their embassy in Washington, D.C. Such formal arrangements must be requested by the user directly through their Scientific Attaché.
Source: http://www.ncdc.noaa.gov